home
   

Gyroscope Benefits 

System Applications 

System Components 

Test Results / Demo

Sensor Comparisons

Publications

About Motus

This email address is being protected from spambots. You need JavaScript enabled to view it.


Motus Bioengineering Inc.
Quantify Movement Disorders with a Gyroscope
The New Standard for Neurologists, Neurosurgeons, & Physical Therapists

 

Data Files for Ch 21: "The Poetics of Tremor" in: Modeling in the Neurosciences  2nd Edition     Chapter Authors: Moore & Bronte-Stewart

     File Structure

Filename Containing Comments n/a Col 1 Col 2 Col 3 Col 4 Col 5 Col 6 Col 7
Data used in Figures: n/a
ChFig1 Data Fig 1 RH rest tremor, pronation-supination, pronation +  Sampling rate:100/sec   Sensor, RH measuring P+/S, deg/sec Data not shown in Figure n/a n/a n/a n/a n/a
ChFig2 Data Fig 2 RH rest tremor with R forearm extensor and flexor EMGs. Flexion +   time, sec Sensor 1, RH measuring F+/E, deg/sec EMG1: Extensors, mv EMG2: Flexors, mv n/a n/a n/a
ChFig3 Data Fig 3 Concurrent resting tremors, four extremities   time, sec Sensor 1, RH measuring P+/S, deg/sec Sensor 2, LH measuring P+/S, deg/sec Sensor 3, RL measuring ankle F+/E, deg/sec Sensor 4, LL measuring ankle F/E+, deg/sec n/a n/a
ChFig4 Data Fig 4 Bi-axial hand tremor, RH Sampling rate: 100/sec   Sensor 1, RH measuring P+/S deg/sec Sensor 2, RH measuring F+/E deg/sec n/a n/a n/a n/a n/a
ChFig5 Data Fig 5 Concurrent rest tremors, RH, LH.   Sampling rate: 100/sec                 Sensor 2 shown   Sensor 1, LH measuring P/S+   deg/sec Sensor 2, RH    measuring P+/S  deg/sec n/a n/a n/a n/a n/a
ChFig6 Data Fig 6 Bi-axial, bilateral records, RH, LH. LH rest tremor, RH voluntary P/S              Sensors 2 and 4 shown   Time, sec Sensor 1, RH measuring P+/S    deg/sec Sensor 2, LH measuring P+/S    deg/sec Sensor 3, RH measuring F+/E    deg/sec Sensor 4, LH measuring F/E+    deg/sec n/a n/a
ChFig7 Data Fig 7 Bilateral postural tremor    Sensor 2 shown   Time, sec Sensor 1, RH   measuring F+/E   deg/sec Sensor 2, LH  measuring F/E+  deg/sec n/a n/a n/a n/a
ChFig8 Data Fig 8 Action tremor LH  Accompanies voluntary LH P/S  Sensor 2 shown   Time, sec Sensor 1, RH measuring P+/S  deg/sec Sensor 2, LH measuring P+/S  deg/sec n/a n/a n/a n/a

               

Filename Containing Supplementary Data:   Col 1 Col 2 Col 3 Col 4 Col 5 Col 6 Col 7
ChFig2s1 Fig 2 Supplement Data, Tremor and EMG Bilateral resting tremors, RH & LH; with R forearm extensor EMG, R forearm flexor EMG, L forearm extensor EMG, L forearm flexor EMG   Time, sec Sensor 1, RH measuring P/S+      deg/sec Sensor 2, LH measuring P+/S   deg/sec EMG1: R Ext EMG2: R Flx EMG3: L Ext EMG4: L Flx
ChFig2s2  " Bilateral postural tremors and EMGs as in ChFig2s1   n/a n/a n/a n/a n/a n/a n/a
ChFig2s3  " Bilateral postural tremor and EMGs as in Fig2s1 but measuring F/E   n/a Wrist flexion + Wrist extension + n/a n/a n/a n/a
ChFig3s1 Fig 3  Supplement Data Concurrent postural tremors, all four extremities   Time, sec Sensor 1 RH measuring P+/S       deg/sec Sensor 2 LH  measuring P+/S         deg/sec Sensor 3, RL  measuring F+/E       deg/sec Sensor 4, LL  measuring F/E+       deg/sec n/a n/a
ChFig4s1 Fig 4 Supplement Data Bi-axial RH rest tremor   as in Fig. 4, sampling rate 100/sec                           Sensor 1 RH measuring P+/S deg/sec Sensor 2 measuring F+/E deg/sec n/a n/a n/a n/a n/a
ChFig7s1 Fig 7 Supplement Data Resting tremor record, LH  Use Sensor 2   Time, sec Sensor 1, RH measuring P+/S Sensor 2, LH measuring P+/S n/a n/a n/a n/a
ChFig7s2 Fig 7 Supplement Data Postural tremor record, LH  Use Sensor 2,      Same subject as ChFig7s1   Time, sec Sensor 1, RH measuring P+/S Sensor 2, LH measuring P+/S n/a n/a n/a n/a
ChFig7s3 Fig 7 Supplement Data Postural tremor record, LH  Use Sensor 2,      Same subject as ChFig7s1   Time, sec Sensor 1, RH measuring P+/S Sensor 2, LH measuring P+/S n/a n/a n/a n/a
ChFig7s4 Fig 7 Supplement Data Resting tremor record, LH  Use Sensor 2,        Same subject as ChFig7s1   Time, sec Sensor 1, RH measuring P+/S Sensor 2, LH measuring P+/S n/a n/a n/a n/a
ChFig7s5 Fig 7 Supplement Data Resting tremor record, LH    Use Sensor 2,   Same subject as ChFig7s1   Time, sec Sensor 1, RH measuring P+/S Sensor 2, LH measuring P+/S n/a n/a n/a n/a
ChFig7s6 Fig 7 Supplement Data Postural tremor record, LH  Use Sensor 2,     Same subject as ChFig7s1   Time, sec Sensor 1, RH measuring P+/S Sensor 2, LH measuring P+/S n/a n/a n/a n/a
ChFig8s1 Fig 8  Supplement Data RH Action Tremor with P/S; concurrent LH rest tremor   Time, sec Sensor 1, LH measuring P+/S deg/sec Sensor 2, RH measuring P+/S deg/sec n/a n/a n/a n/a
ChFig8s2  " LH Action Tremor with P/S; concurrent RH rest tremor.  Same subject as ChFig8s1   Time, sec Sensor 1, LH measuring P+/S deg/sec Sensor 2, RH measuring P+/S deg/sec n/a n/a n/a n/a
ChFig8s3  " RH action tremor with RH pronation-supination   Time, sec Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a n/a
ChFig8s4  " LH action tremor with LH pronation-supination       Same subject as ChFig8s3   Time, sec Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a n/a
Problem Set Data:    
ChProb3 Problem 3 Data Bilateral (RH, LH), bi-axial tremor data, 30 sec   Time, sec Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec Sensor 3, RH measuring F+/E deg/sec Sensor 4, LH measuring F/E+ deg/sec n/a n/a
ChProb3b  " Four concurrent resting tremors; all four extremities; same subject as ChProb3c   Time, sec Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec Sensor 3, RL measuring F+/E deg/sec Sensor 4, LL measuring F/E+ deg/sec n/a n/a
ChProb3c  " Four concurrent resting tremors; all four extremities; same subject as ChProb3b   Time, sec Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec Sensor 3, RL measuring F+/E deg/sec Sensor 4, LL measuring F/E+ deg/sec n/a n/a
ChProb4a Problem 4 Data Single central neuron and two concurrent rest tremors, 30 sec record   Time, sec Microelectrode record volts Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a
ChProb4b Problem 4 Data Single central neuron and two concurrent rest tremors, 46 sec record   Time, sec Microelectrode record volts Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a
ChProb4c Problem 4 Data Single central neuron and two concurrent rest tremors, 31 sec record   Time, sec Microelectrode record volts Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a
ChProb4d Problem 4 Data Single central neuron and  concurrent postural tremor, 28 sec record                           Time, sec Microelectrode record volts Sensor 1, RH measuring F+/E deg/sec n/a n/a n/a n/a
ChProb4e Problem 4 Data Single central neuron and two concurrent rest tremors, 61 sec record   Time, sec Microelectrode record volts Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a
ChProb4f Problem 4 Data Single central neuron and two concurrent rest tremors, 38 sec record   Time, sec Microelectrode record volts Sensor 1, RH measuring P+/S deg/sec Sensor 2, LH measuring P+/S deg/sec n/a n/a n/a

                      

NOTES:

* The data listed here may also be found: www.neurosciences.glasgow.ac.uk~book  

* F+/E means flexion-extension movement with flexion positive

* P/S+ means pronation-supination with supination positive

* Sensors refer to angular velocity measuring devices manufactured by Motus Bioengineering Corp., Benicia, California   www.motusbioengineering.com

* Data including single neuron signals, emgs and sensors were acquired using a data acquisition system built by Axon Instruments, Inc., Union City, California

* Comments or inquiries: contact gmoore@usc.edu

 

 

     

               


 


Motus Bioengineering Inc.
133 Carlisle Way,  Benicia, Calif. 94510

  Gary Felsing  707- 745-4194    Fax: 707-745-5551

e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
home page:  www.MotusBioengineering.com 

hosting by www.Internet-addresses.com